Przeglądanie stron 0
Cat. No. 01020480
Rev. A
2
11/15/07
DCO # 010173
Installation
and Operation
Instructions
with Parts List
Culligan Medallist and
Medallist Plus Series
®
Automatic Water Filters
with Cullar
®
, Cullneu
®
, or Cullsan
®
Media
Models from 2007
© 2007 Culligan International Company
Przeglądanie stron 0
1 2 3 4 5 6 ... 41 42

Podsumowanie treści

Strona 1 - Medallist Plus Series

Cat. No. 01020480Rev. A2 11/15/07DCO # 010173Installation and Operation Instructions with Parts ListCulligan Medallist and Medallist Plus Series®Auto

Strona 2 - Rosemont, IL 60018

Filtr-Cleer® Water FilterThe 8” Filtr-Cleer lters are shipped with one media pack and the 10” Filtr-Cleer lters are shipped with two media packs. Ve

Strona 3

Cullneu® FiltersCullneu lters are shipped with 2 bags of Cullneu with 8” lters and 3 bags of Cullneu with 10” lters. Verify that the proper amount

Strona 4 - Introduction

InstallationPlacementRefer to Figure 3 for system placement.• Set the media tank on a solid, level surface near water, drain and electrical facilitie

Strona 5 - Specifications and Limitations

Installation 10Mount The Control Valve - 1” ControlSee Figure 6 for a visual on mounting the control valve to the tank.• Assemble the o-rings, loc

Strona 6 - Component Description

For backwash ow control conversion, refer to Figure 8 and instructions listed below.• Remove the u-clip of the drain elbow assembly and pull the dra

Strona 7 - Preparation

Installation 12Bypass Valve Installation - 3/4” Medallist Time Clock Units OnlyThe bypass valve connects directly to the backplate of the valve wi

Strona 8 - Temperature

To bypass, turn the blue knob clockwise (see directional arrow on end of knob) until the knob stops as shown. DO NOT OVERTIGHTEN! (Figure 12a).To retu

Strona 9 - Tools and Materials

Settings Settings 14Your Culligan Medallist Water Filter is designed to perform efciently on a wide range of water supplies. Before the unit can b

Strona 10 - Filling Procedure

15 Culligan Medallist Series® Water FiltersCircuit Board ConnectionsRefer to Figure 14 for all circuit board connections. Power terminals are locat

Strona 11 - Filters

ProgrammingDip Switch DenitionsThe circuit board is shipped with all DIP switches in the off position. Prior to programming the controller some DIP s

Strona 12 - Installation

Attention Culligan Customer:Your local independently operated Culligan dealer employs trained service and maintenance personnel who are experienced in

Strona 13 - Install the Flow Control

The programming menu for Medallist is outlined in the following table:Setting Display Range Limits Default CommentsTime of Day 12:00 AM - 11:59 PM (12

Strona 14 - Bypass Connections

Programming 18The timer uses four buttons:Button DescriptionSet-up / Enter Key (Status) Advance timer through display optionsRegeneration Key (REGE

Strona 15 - Installation 12

Settline TimeThis setting is used to set the time in minutes for cycle 2. This cycle is a settling time for lters. The display will show “br” in the

Strona 16 - Electrical Connections

Programming 20Screen LockingThis setting is used to lock out the user from changing most of the program menu settings. When the “Loc” setting is sa

Strona 17 - Settings

Manual Control CyclingThe control can be manually cycled through a regeneration to troubleshoot the control or verify that the set-up is complete. Whe

Strona 18 - Circuit Board

1. Press the status button to move past the programming steps until the display is blank. From blank display press the “+” key. An “H” will appear

Strona 19 - Programming

The service mode allows one to view the number of regenerations in the past 14 days, the total number of regenerations the control has cycled through

Strona 20 - Hidden Programming Menu

This display will show the total number of regenerations that have occurred since installation. The display will show “totL” for two seconds and then

Strona 21 - Backwash Time

25 Culligan Medallist Series® Water FiltersCullar® and Cullneu® Water Filters• Connect the transformer to a grounded, 120 Volt, 60 Hertz outlet.•

Strona 22 - Water Filters

Troubleshooting GuideProblem Cause Solution1. Unit has blank display. A. Unit has no power. A. Verify that unit is connected to a constant power so

Strona 23 - Screen Locking

Installation and Operation Instructions with Parts ListCulligan Medallist and Medallist Plus Series®Automatic Water Filterswith Cullar®, Cullneu®, or

Strona 24 - Manual Cycling

27 Culligan Medallist Series® Water FiltersProblem Cause Solution6. Loss of mineral to drain. A. Improper drain line ow control. A. Ensure that

Strona 25 - Manual Cycling 22

Circuit Board TroubleshootingError ModeWhen a failure is detected, the control will generate and display an error or alarm code, depending on the type

Strona 26 - Service Check

Listed below are some other circuit board problems and their explanations:– Board skips the service position or only stops for a second in service be

Strona 27 - Statistical Function Timeout

Test Description Display Information Action TriggerStart Test Mode All LCD segments lit DIP switch #1 set to on, all others offSoftware version Softwa

Strona 28 - Start-up Procedure

Operation, Care & MaintenanceCullneu® Water Filter RefillAs water passes through the Cullneu Water Filter, the media slowly dissolves and neutraliz

Strona 29 - Troubleshooting Guide

Care and CleaningProtect the operation and appearance of the water lter by following these precautions:• Do not place heavy objects on top of the co

Strona 30

Wiring DiagramYELREDBRNBRNCIRCUIT BOARDGEARMOTORBLK BLKBLKBLKBLKBLKCIRCUIT BOARDBRNBRNREDYELGEARMOTORMOTORHOMESWITCH(BOTTOM)MOTORPOSITIONSWITCH(TOP)PO

Strona 31 - Circuit Board Troubleshooting

Parts List3/4" FILTER VALVE1" FILTER VALVE14161526202511318475518172925202615161417181811830652423222126529 30652423222126513183/4” Filter V

Strona 32 - Test Mode

35 Culligan Medallist Series® Water Filters86310931256363473636336311636565656565651” Filter Valve348491098633126345637363636311636565656565653/4” F

Strona 33

82837184727050585952576059435751555354568385728482A72 Parts List 36

Strona 34 - Cul-Flo-Valv Bypass

This system and installation must comply with state and local regulations.For installations in Massachusetts, the Commonwealth of Massachusetts Plumbi

Strona 35 - Care and Cleaning

37 Culligan Medallist Series® Water FiltersPower Valve Service Parts ListItem # Part # DESCRIPTION Quantity/PackValve Size3/4” Valve 1” Valve1A 0101

Strona 36 - Wiring Diagram

Item # Part # DESCRIPTION Quantity/PackValve Size3/4” Valve 1” Valve52A 01013958 Tank Adapter, 1” Valve 1 Each X52B 00444808 Tank Adapter, 3/4” Valv

Strona 37 - Parts List

Filter Tank 39 Culligan Medallist Series® Water FiltersPart No. Description00441897 Replacement Tank, 8”, w/ Manifold, Empty01014892 Replacement Tank

Strona 38 - 3/4” Filter Valve

8 Inch Medallist 10 Inch Medallist 10 Inch Medallist PlusGeneralMineral Tank Size18 x 44 in. 10 x 54 in. 10 x 54 in.Control 3/4” Power Valve 3/4” Powe

Strona 39 - Parts List 36

Component Description 3 Culligan Medallist Series® Water FiltersControl Valve AssemblyThe reliable Power Valve directs the ow of water during recha

Strona 40

Preparation Preparation 4The success of the installation will depend to a great extent on advance planning and preparation. Careful attention to the

Strona 41 - Parts List 38

PressureThe lter is designed to operate within a pressure range of 20 to 125 psi. Pressures below 20 psi may cause the unit to perform and recharge i

Strona 42 - Filter Tank

LocationSpace requirements - Allow 6-12 inches (15-30 cm) behind the unit for plumbing and drain lines.Floor surface - Choose an area with solid, leve

Komentarze do niniejszej Instrukcji